 |
Facilities

Stage Dimensions:
Pros Height: 5.00mt.
Stage Depth: 7.50mt.
Height of Stage: 1.28mt.
Grid Height: 12.00mt.
Stage Left wing: 2.00mt.
Storage: Limited.
Truck Access: Reasonable access for all size trucks.
Pros Width: 8.20mt.
Stage Width: 12.20mt.
Performance Area: 91.50 sq. mt.
Stage Floor: Marine plywood, painted black.
Stage Right Wing: 2.00mt.
Crossover: Behind Stage.
Rigging:
Flytower: Yes.
Grid Height: 12.00mt.
Maximum Setting: 5.75mt.
Raise & Lower System: 16 sets, 3 wire rated @ 250kg. Sets 2/Lx, 6/Lx, 8, 10/Lx, 13/Lx & 15 are operated by motorised pilewinds. Remaining sets are operated by drill controlled piewinds.
Length of Hauling Bar: 10.00mt.
Spacing between Bars: 350mm.
Maximum S.W.L. 250kg.
Lighting:
Lighting Circuits: 120 into 120/72 Patch Panel
Cir 1 - 18
Cir 19 - 24
Cir 25 - 30
Cir 31 - 42
Cir 43 - 54
Cir 55 - 66
Cir 67 - 78
Cir 79 - 84
Cir 85 - 90
Cir 91 - 96
Cir 97 - 102
|
FOH Bridge
Left FOH Boom
Right FOH Boom
Lx. No. 1
Lx. No. 2
Lx No. 3
Lx. No. 4
DSL facility panel
USL facility panel
USR facility panel
DSR facility panel |
Dimming:
72 ways of 2.5kW dimming - Strand LD 90.
Located: Stage Right wall.
Control: ETC 250 Express.
control protocol: DMX 512.
Riggers Remote: Yes.
Visiting Supply: 63Amp 3 Phase.
Number of DMX points: 7
Lantern Stock:
Quantity: Type:
20 No. SL. 15/30
10 No. SL. 23/50
30 No. Cantata F
40 No. Par Cans
12 No. Iris floods
1 No. iFollow spot
Cables:
50 No. 10mt x 16A - 16A.
50 No. 5mt x 16A - 16A.
20 No. 2.5mt x 16A - 16A
Non Dim Circuits:
3 No. DSL.
3 No. DSR.
Non dim circuits controlled from Control Room.
Sound:
Re-enforcement:1 No. Martin 5kW PA system, inc of 6 Martin EM76 loudspeakers and 2 Martrin EM201 sub units.
Control:1 No. Allen & Heath 2200 / 32 mixing desk.
Outboard Rack:1 No. Power protection unit. 3 No. DDB 32 band graphics. 2 No.Berhinger compressors. 2 No. Lexicon MPX200 effects units. 2 No. Tascam MD301 mini disc players. 2 No. Tascam CD160 cd players.
Monitors: 2 No. Crown XLS 402 amplifiers. 4 No. Martin F12 monitors.
Mics & DI's: 6 No. Shure SM 58. 2 No. Shure SM 57. 2 No. Audio Technic 61HE. 8 No. Behringer DI 100 DI boxes.
Drapes:
2 No. - 10mt x 6mt trailer curtains, wool serge.
10 No. - 1.50mt x 6mt masking legs, wool serge.
3 No. - 10mt x 2mt borders, wool serge.
Cyclorama:
1 No. - White filled cyclorama cloth.
FOH Curtain:
1 No. - Aqua Marine House Curtain, velour.
Backstage accommadation:
Dressing Room 1 - 6 person
Dressing Room 2 - 20 person
Dressing Room 3 - 6 person
Dressing Room 4 - 6 person
Green Room: Yes
Kitchen: Yes
Toillets and showers located on first and second floor corridors.
*Please note Dressing No 1 is the only dressing room with disabled access.
Comms:
6 No. Headsets and beltpacks.
1 No. Master Station in S.M. corner.
All dressing rooms have speaker stations, headset outlets are located in all facility panels, fly floor, control room and FOH gantry.
|
|